The working principle of the bimetallic strip drain valve is based on the bimetallic strip temperature sensing element. This type of valve contains a bimetallic sensing element. When the steam temperature changes, the bimetallic element will deform due to heat, thereby pushing the valve core to open and close the valve. Specifically, as the steam temperature increases, the bimetallic strip will bend in one direction, and as the temperature decreases, it will return to its original state in another direction. This deformation drives the valve core switch, controls the discharge of condensed water, air, and other non condensable gases, and prevents steam leakage. The bimetallic plate drain valve produced by Shanghai Meiyan Yi Pump Valve has adjustment bolts inside, which can adjust the operating temperature according to needs. The general undercooling adjustment range is below the saturation temperature by 15 ℃ -30 ℃, the back pressure rate is greater than 70%, it can discharge non condensable gases, is resistant to freezing, has a small volume, can withstand water hammer, high pressure, and can be installed at any position.