Your location:
The two positions of the two position five way solenoid valve refer to the two working positions of the solenoid valve core: when the solenoid valve is not powered, P-A is connected, B-S is connected, and R is blocked; When the solenoid valve is powered on, A-R is connected, P-B is connected, and S is blocked. The five way valve refers to a solenoid valve with five air pipe interfaces (A, B, R, P, S). The working principle of a two position five way solenoid valve is that the solenoid valve has a closed chamber with through holes at different positions, each hole leading to a different channel. The middle of the chamber is the piston, and there are two electromagnets on both sides. The magnetic coil on which side is energized will attract the piston to which side. By controlling the movement of the piston to block or leak out different holes, the piston drives the piston rod, which in turn drives the mechanical device to move. In this way, the mechanical motion is controlled by controlling the current of the electromagnet.